APC Metered-by-Outlet Rack PDU 2G - Power distribution unit (rack-mountable) - AC 400 V - 3-phase - RS-232 - output connectors: 24 - 0U - black - for P / N: SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT5KRMXLW-TW
APC Metered-by-Outlet Rack PDU 2G - Power distribution unit (rack-mountable) - AC 400 V - 3-phase - RS-232 - output connectors: 24 - 0U - black - for P / N: SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT5KRMXLW-TW
Ražotājs
•SCHNEIDER
Ražotāja kods
•AP8481
Artikuls
•1270803
Intrastat
•85044090
Pakas svars
•10.48 kg
<ul><li>Metering-by-outlet capability</li><li>Network management capabilities</li><li>Alarm thresholds</li><li>Local current monitoring display</li><li>Load indicator LED</li><li>Flash upgradeable</li><li>Integrates with StruxureWare Data Center Expert</li></ul>
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.<br /><br /><p> </p>
Device Type
Power distribution unit - rack-mountable
Height (Rack Units)
0U
Colour
Black
Input Voltage
AC 400 V
Input Wiring
3-phase
Frequency Required
50/60 Hz
Input Connectors
Power IEC 60309 16A, power IEC 60309 20A
Power Output Connectors Details
21 x power IEC 60320 C13 ¦ 3 x power IEC 60320 C19
Output Voltage
AC 230 V
Max Electric Current
16 A
Remote Management Interface
RS-232
Remote Management Protocol
SNMP, Telnet, HTTP
Interfaces
1 x management (RS-232)
Cables Included
Power cable 1.83 m ¦ Serial cable - external
Rack Mounting Kit
Included
Features
LCD display, LED indicators, overload protection, vertical orientation, firmware upgradable
Compliant Standards
UL, EN 61000-3-2, ICES-003, VDE, EN 61000-3-3, EN55024, EN55022 Class A, RoHS, FCC Part 15 A, REACH
Service & Support
Limited warranty - 2 years
Min Operating Temperature
-5 °C
Max Operating Temperature
45 °C
Humidity Range Operating
5 - 95%
Width
5.6 cm
Depth
5.1 cm
Height
182.9 cm
Weight
8.21 kg
Shipping Width
16.3 cm
Shipping Depth
11.7 cm
Shipping Height
203.7 cm
Shipping Weight
10.48 kg
Designed For
P/N: AP5607, AP7950B, AR2200, AR2280, AR2400, AR2400FP1, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR3100G, AR3100TAA, AR3100W, AR3100X609, AR3100X610, AR3100X617, AR3105, AR3105SP, AR3105W, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3150SP, AR3150W, AR3150X609, AR3150X610, AR3150X617, AR3155, AR3155SP, AR3155W, AR3157SP, AR3157X609, AR3157X610, AR3157X617, AR3180G, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3305, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3350SP, AR3350W, AR3350X609, AR3350X610, AR3350X617, AR3355, AR3355SP, AR3355W, AR3357SP, AR3357X609, AR3357X610, AR3357X617, AR3357X674, NBES0302, NBPD0160A, NBPD0171, NBPD0172, NBPD0180, NBWL0355A, NBWL0356A, SMC1000, SMC1000-2U, SMC1000-BR, SMC1000I, SMC1000I-2U, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC1500, SMC15002U-BR, SMC1500-BR, SMC1500I, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I-2U, SMC3000RMI2U, SMT1500RM1U, SMT150