APC Switched Rack PDU 2G Zero U - Power distribution strip (rack-mountable) - AC 200 / 208 / 230 V - RS-232 - input: IEC 60320 C20 - output connectors: 8 - black - for P / N: AR3106SP, SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT5KRMXLW-TW

APC Switched Rack PDU 2G Zero U - Power distribution strip (rack-mountable) - AC 200 / 208 / 230 V - RS-232 - input: IEC 60320 C20 - output connectors: 8 - black - for P / N: AR3106SP, SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT5KRMXLW-TW

Manufacturer
APC
Reference
AP8958
Article
485482
Intrastat
85044090
Shipping weight
4.8 kg
<ul><li>Network Management Capabilities</li><li>Remote Individual Outlet Control</li><li>Alarm Thresholds</li><li>Local Current Monitoring Display</li><li>Power Delays</li><li>Load indicator LED</li><li>Flash Upgradeable</li><li>Integrates with StruxureWare Data Center Expert</li></ul> APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.<br /><br /><p> </p>

All offers are visible after login.

Manufacturer
APC
Reference
AP8958
Article
485482
Intrastat
85044090
Shipping weight
4.8 kg
<ul><li>Network Management Capabilities</li><li>Remote Individual Outlet Control</li><li>Alarm Thresholds</li><li>Local Current Monitoring Display</li><li>Power Delays</li><li>Load indicator LED</li><li>Flash Upgradeable</li><li>Integrates with StruxureWare Data Center Expert</li></ul> APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.<br /><br /><p> </p>

Device Type
Power distribution strip - rack-mountable
Colour
Black
Input Voltage
AC 200/208/230 V
Input Voltage Range
AC 100 - 240 V
Frequency Required
50/60 Hz
Input Connectors
1 x power IEC 60320 C20
Power Output Connectors Details
1 x power IEC 60320 C19 ¦ 7 x power IEC 60320 C13
Output Voltage
AC 200/208/230 V
Max Electric Current
16 A
Remote Management Interface
RS-232
Remote Management Protocol
SNMP, Telnet, HTTP
Interfaces
1 x management
Cables Included
Power cable ¦ Serial cable - external
Rack Mounting Kit
Included
Features
LCD display
Compliant Standards
UL, cUL, EN 61000-3-2, EN55022, ICES-003, VDE, VCCI Class A ITE, EN 61000-3-3, EN55024, RoHS, FCC Part 15 A, PSE Mark, REACH
Service & Support
Limited warranty - 2 years
Min Operating Temperature
-5 °C
Max Operating Temperature
45 °C
Humidity Range Operating
5 - 95%
Width
5.6 cm
Depth
4.6 cm
Height
98.8 cm
Weight
3.2 kg
Shipping Width
16.5 cm
Shipping Depth
11.4 cm
Shipping Height
113 cm
Shipping Weight
4.8 kg
Designed For
P/N: AP6221CH, AR2200, AR2280, AR2487G, AR3100G, AR3100TAA, AR3100W, AR3103SP, AR3105SP, AR3105W, AR3106SP, AR3107G, AR3107SP, AR3140G, AR3140W, AR3150SP, AR3150W, AR3155SP, AR3155W, AR3157SP, AR3180G, AR3300G, AR3300SP, AR3300W, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3340G, AR3340W, AR3350SP, AR3350W, AR3355SP, AR3355W, AR3357SP, AR3357X674, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4038IX432, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, DLT3000RMI2U, NBES0302, NBPD0160A, NBPD0180, NBWL0355A, NBWL0356A, SMC1000-BR, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC15002U-BR, SMC1500-BR, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I, SMC2000I-2U, SMC3000I, SMC3000RMI2U, SMT1500RM1U, SMT2200I-AR, SMT2200IC, SMT2200R2I-AR, SMT2200RM2UC, SMT2200RMI2UC, SMT2200RMI2UNC, SMT3000I2U-BR, SMT3000I-AR, SMT3000IC, SMT3000R2I-6W, SMT3000R2I-AR, SMT3000RM2UC, SMT3000RMI2UC, SMT3000RMI2UNC, SMX1000C, SMX1000US, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2000LVNCUS, SMX2000LVUS, SMX2200H

NetBotz - Smoke sensor - wired - 10 / 100 Ethernet